Defining New Reference Intervals for Serum Free Light Chains in Individuals with Reduced Kidney Function: Results of the Population- Based on iStopMM Study
In addition to serum protein electrophoresis (SPEP) and serum immunofixation (IFE), measurement of serum free light chains (FLC) has become the hallmark for detection, prognostication, and monitoring of monoclonal gammopathies. However, serum FLC levels are heavily dependent on kidney function due to discrepancy in the rate of kidney clearance of the FLC. As chronic kidney disease (CKD) is common in the general population, it is possible that a large number of individuals have false FLC results. A kidney reference interval (eGFR less than 60) has previously been published based on small numers (N=688) for serum FLC ratio (0.37–3.10) instead of the standard reference interval (0.26-1.65), but no kidney reference exists for kappa (3.3–19.4mg/L) or lambda (5.7–26.3mg/L). The aim of this study was to define and improve the reference interval for individuals with various degree of decreased kidney function and assess its effect on prevalence of light chain monoclonal gammopathy of undetermined significance (LC-MGUS) among CKD patients.
Conclusion:
Current reference intervals for serum FLC and FLC ratio are inaccurate for patients with decreased kidney function. Here we propose new reference intervals for serum FLC and FLC ratio for use in patients with CKD which also seem to be accurate in patients on dialysis. Implementing these novel reference intervals is likely to increase the sensitivity and specificity of the analyses and lead to a more accurate diagnosis of monoclonal gammopathy in individuals with kidney dysfunction.
ASH 2021: Abstract 542